Environmental Tests

Environmental test chamber, test chamber volume: 190 ltr

  • Cold from –70°C, according to DIN EN 60068-2-1
  • Heat until +180 °C, according to DIN EN 60068-2-2 / DIN EN 60068-2-14
  • Humidity (10 – 99% rH), constant and cyclic according to DIN EN 60068-2-30, -2-67, -2-78
  • Temperature changes with specified rate of change according to DIN EN 60068-2-14
  • Climate stress screening with temperature change rate up to 4K / min
  • Composite test temperature / humidity, cyclic according to DIN EN 60068-2-38

Environmental Tests

Environmental test chamber, test chamber volume: 408 ltr

  • Cold from –40°C, according to DIN EN 60068-2-1
  • Heat until +150 °C according to DIN EN 60068-2-2 / DIN EN 60068-2-14
  • Humidity (20 – 98% rH) according to DIN EN 60068-2-30, -2-67, -2-78
  • Temperatur changes with specified rate of change up to 3K / min according to DIN EN 60068-2-14